- 400a primary to 50ma secondary current ratio for high-capacity ac input sensing in multiplus-ii external transfer switch systems.
- 10m cable with stripped and tinned wire ends for direct push-in terminal connection on compatible multiplus-ii and multiplus 20kw units.
- One transformer per phase, connected to the master unit, to detect ac input availability and control the external transfer switch.
- Requires external transfer switch ve.bus firmware (s99); for standard multiplus-ii grid-current sensing use the 100a:50ma current transformer instead.
- Victron part ctr140050100, designed for external transfer switch systems supporting up to 12 multiplus(-ii) units with a maximum of 4 per phase.
The Victron 400A:50mA Current Transformer is designed for MultiPlus-II and MultiPlus 20kW systems configured with an external transfer switch, where it replaces the internal AC transfer switch function. One transformer is fitted per phase and connected to the master unit of that phase, which uses it to determine whether AC input is available and to control the external transfer switch. This model (CTR140050100) has a 10-metre cable with stripped and tinned wire ends for direct push-in terminals on compatible units, and it requires the External Transfer Switch VE.Bus firmware (s99). Victron notes the 400A transformer has reduced current sensing resolution, especially at low currents, and states it can only be used in an external transfer switch application; for general grid-current sensing, PowerControl, PowerAssist or self-consumption optimisation on a standard MultiPlus-II, the 100A:50mA Current Transformer is the appropriate choice.